Shop solar fuses and breakers from MidNite Solar, Victron Energy, and Elios for off-grid, RV, marine, and residential solar systems across Canada. Choose from MidNite Solar MNEPV PV breakers from 4A to 100A, Victron Energy MEGA, MIDI, and ANL fuse holders and busbars, the Elios 6-Way ATO fuse box, and MidNite Solar MNPV6 combiner boxes. Every unit ships nationwide from Volts Energies with free shipping on orders over $297.

View as


Why DC Overcurrent Protection Is Non-Negotiable

Unlike AC circuits where a utility breaker provides upstream protection, DC battery systems have no external overcurrent device between the battery and the rest of the installation. A battery bank at full charge can deliver thousands of amps into a short circuit in milliseconds, enough to vaporize cable insulation, ignite nearby materials, and destroy connected equipment before a slow-acting fuse responds. 

Every DC circuit requires a correctly sized, DC-rated fuse or breaker installed as close to the positive battery terminal as the installation allows, with an interrupt rating that exceeds the battery's maximum short-circuit current.

Victron Energy Fuse Holders

Buy Victron Energy fuse holders for MEGA, MIDI, and ANL fuse formats, each designed for a specific current range and application in 12V, 24V, and 48V DC systems.

The MEGA fuse holder accepts MEGA-format fuses rated from 30A to 300A at 32V or 58V (48V systems). MEGA fuses are specified by Victron for use in the Lynx Distributor and for branch circuit protection on inverter charger DC inputs in 12V and 24V systems. The fuse holder provides a secure, single-fuse installation point for systems without a Lynx distribution module.

The MIDI fuse holder accepts MIDI-format fuses rated from 30A to 200A. MIDI fuses are smaller than MEGA fuses and are commonly used for branch circuit protection on MPPT charge controllers, DC loads, and secondary battery banks where lower interrupt current ratings are acceptable.

The ANL fuse holder accepts ANL-format fuses typically rated from 80A to 400A. ANL fuses provide a cost-effective high-current protection option for battery-to-inverter connections in 12V and 24V systems where the installation does not require Class-T fuse interrupt ratings.

Victron Energy CNN Fuse

Order the Victron CNN fuse (325A/80V) for high-current DC applications requiring a bolted, high-interrupt-capacity fuse at the main battery connection in 12V, 24V, or 48V systems. The CNN format provides higher interrupt ratings than standard MEGA or ANL fuses, making it appropriate for large LiFePO4 battery banks capable of delivering high short-circuit currents.

Midnite Solar MNEPV DC Circuit Breakers

Buy Midnite Solar MNEPV series circuit breakers for PV array overcurrent and disconnect protection on solar charge controller inputs. Available in 15A, 20A, 30A, 40A, 63A, and 100A ratings, all rated to 300VDC for use on the PV positive conductor between the solar array and MPPT charge controller. DIN rail mountable. ETL is listed for the USA and Canada. Used in combiner boxes, solar enclosures, and any installation requiring a DC-rated disconnect and overcurrent device on the PV source circuit. Select the amperage based on the charge controller's maximum PV input current, not the array's total short-circuit current.

Blue Sea Systems ST Blade Fuse Block

Install the Blue Sea ST Blade Fuse Block (5025) for protected distribution of DC branch circuits, 6 circuits with a common negative bus and cover. Suitable for 12V and 24V DC accessory circuits in marine, RV, and vehicle installations where multiple loads require individual fuse protection from a common positive supply. ATO/ATC blade fuse format, widely available in ratings from 1A to 40A.

Elios 6-Way ATO Fuse Box

Choose the Elios 6-Way ATO fuse box for a compact, covered blade fuse distribution block in van builds, marine panels, and off-grid DC distribution boards requiring protected branch circuits without a full distribution system.

Fuse Type Selection Guide

Choose the fuse type based on your system's current, voltage, and application.

MEGA Fuse

  • Current Range: 30A–300A
  • Voltage Rating: 32V or 58V
  • Typical Use: Inverter branch circuits, Lynx Distributor systems, and 12V–48V battery installations.

MIDI Fuse

  • Current Range: 30A–200A
  • Voltage Rating: 32V or 58V
  • Typical Use: MPPT solar charge controllers, secondary battery banks, and DC load protection.

ANL Fuse

  • Current Range: 80A–400A
  • Voltage Rating: 32V
  • Typical Use: Main battery-to-inverter connections in 12V and 24V systems.

CNN Fuse

  • Current Rating: 325A
  • Voltage Rating: 80V
  • Typical Use: High-current main battery protection for large LiFePO4 battery banks.

MNEPV (MidNite) Fuse

  • Current Range: 15A–100A
  • Voltage Rating: 300VDC
  • Typical Use: PV array source circuits, solar combiner boxes, and MPPT controller inputs.

ATO/ATC Blade Fuse

  • Current Range: 1A–40A
  • Voltage Rating: 32V
  • Typical Use: DC accessory circuits, marine electrical panels, and RV branch circuits.

FAQs

What Is The Difference Between A Mega Fuse And A Midi Fuse? 

MEGA and MIDI fuses are both bolt-down DC fuses used for overcurrent protection in battery and solar systems, but they differ in physical size and typical current range. MEGA fuses are larger and available from 30A to 300A. MIDI fuses are smaller and available from 30A to 200A. Both formats are available in 32V and 58V ratings, the 58V rating is required for 48V battery systems. MEGA fuses are specified by Victron for use in the Lynx Distributor. MIDI fuses are commonly used for charge controller and secondary battery branch circuit protection.

What Voltage Rating Do I Need For A Fuse In A 48v System? 

Fuses used in 48V battery systems must be rated at a minimum of 58VDC, 125% of the 48V nominal voltage, as required by most DC wiring standards. Standard 32V-rated MEGA, MIDI, or ANL fuses are not suitable for 48V systems and may sustain an arc rather than clearing a fault safely. Victron's 58V MEGA fuses are designed specifically for 48V system protection. Midnite Solar MNEPV breakers are rated to 300VDC, suitable for PV source circuits at any system voltage up to that rating.

What Is The Difference Between An Anl Fuse And A Class-T Fuse? 

Both are high-current DC fuses used for main battery overcurrent protection, but they differ in interrupt capacity. ANL fuses interrupt up to approximately 2,700A and are suitable for lead-acid battery systems where short-circuit current is limited. Class-T fuses interrupt up to 20,000A and are recommended for LiFePO4 battery banks, which can deliver significantly higher short-circuit current than lead-acid batteries due to their lower internal resistance. For lithium battery systems, Class-T fusing at the main battery connection provides a substantially higher margin of safety.

Where Should I Install The Main Battery Fuse? 

Install the main battery fuse, MEGA, ANL, CNN, or Class-T format, as close to the positive battery terminal as the physical installation allows, ideally within 150mm (6 inches). This minimizes the length of unfused cable between the battery and the overcurrent device. The fuse protects the cable and downstream equipment from a fault anywhere in the system. A fuse installed far from the battery leaves a long section of unfused, high-current cable that remains unprotected in a short-circuit event.

What Amperage Midnite Solar MNEPV Breaker Do I Need For My Solar Charge Controller? 

Select the MNEPV breaker amperage based on the MPPT charge controller's maximum PV input current specification, not the solar array's combined short-circuit current. Most Victron SmartSolar MPPT controllers specify maximum PV input current in their datasheet. Choose the next standard breaker size above that value, for example, a 30A breaker for a controller specifying 25A maximum PV input. The 300VDC rating of the MNEPV series accommodates the open-circuit voltage of most series-connected PV string configurations.

Can I Use An Ac Circuit Breaker For Dc Overcurrent Protection? 

No. AC circuit breakers are not rated for DC service and must not be used for DC overcurrent protection. AC current crosses zero 60 times per second, which naturally extinguishes arcs when a breaker opens. DC current does not cross zero, meaning a DC fault arc will sustain and potentially prevent an AC-rated breaker from clearing the fault. DC-rated breakers and fuses, such as the Midnite Solar MNEPV series, are specifically engineered to interrupt DC arcs safely at rated voltage.

What Fuse Format Does The Victron Lynx Distributor Use? 

The Victron Lynx Distributor uses MEGA-format fuses rated at 58V for 48V systems or 32V for 12V and 24V systems. The Lynx Distributor provides four fused DC output positions, each accepting a MEGA fuse from 30A to 300A, allowing individual fuse protection for up to four loads, typically inverter chargers, MPPT controllers, or DC distribution panels, from a common battery busbar. Replacement MEGA fuses are sold separately and are available in this collection.

How Do I Size A Fuse For A DC Circuit? 

Size the fuse to protect the cable, not the load. Identify the ampacity of the cable used in the circuit, determined by wire gauge, length, and installation environment. Select a fuse rated at or below that ampacity. The fuse blows before the cable overheats, preventing insulation damage and fire risk. For main battery-to-inverter cables, also verify that the fuse's interrupt rating exceeds the battery's maximum short-circuit current, particularly important for LiFePO4 battery banks where short-circuit current can reach several thousand amps.